VroniPlag Wiki

This Wiki is best viewed in Firefox with Adblock plus extension.

MEHR ERFAHREN

VroniPlag Wiki


Typus
Verschleierung
Bearbeiter
Hindemith
Gesichtet
Yes
Untersuchte Arbeit:
Seite: 45, Zeilen: 1-17
Quelle: Eisenhauer et al 2007
Seite(n): 17, 18, Zeilen: 17: 20ff; 18: 1ff
These components have a limited set of functionality but could also be deployed on another machine acting as a proxy for e.g. a mote where it would be highly unlikely that those managers would ever be deployed on such a resource-limited device. They have been put on the device by a device manufacturer to provide certain functions irrespective of which application is using the device.

The HYDRA middleware elements are enclosed by the physical and the application layer shown at the bottom and at the top of the diagram respectively. The physical layer realizes several network connections like ZigBee, Bluetooth or WLAN. The application layer contains user applications which could contain modules like workflow management, user interface, custom logic and configuration details. These two layers are not part of the HYDRA middleware. The middleware itself consists of three layers - the network, service and semantic layer, where each layer holds elements according to their functionality and purpose. It is to be noted that some device elements have similar and thus likewise named, counterparts among the application elements. Both, device and application elements, have a Security Manager, which is an orthogonal service and depicted as vertical to cover all three middleware layers.

Those components have a limited set of functionality but could also be deployed on another machine acting as a proxy for e.g. a mote where it would be highly unlikely that those managers would ever be deployed on such a resource-limited device. They have been put on the device by a device manufacturer to provide certain functions irrespective of which application is using the device.

[Seite 18]

The Hydra middleware elements are enclosed by the physical, operating system and the application layer shown at the bottom and at the top of the diagram respectively. The physical layer realizes several network connections like ZigBee, Bluetooth or WLAN. The operating system layer provides functionality to access the physical layer and manages many other hardware and software resources and provides methods to access these resources. The application layer contains user applications which could contain modules like workflow management, user interface, custom logic and configuration details. These two layers are not part of the Hydra middleware. The middleware itself consists of three layers - the network, service and semantic layer. Each layer holds elements according to their functionality and purpose. Note, that some device elements have similar and thus similar named, counterparts among the application elements. Both, device and application elements, have a Security Manager. To express, that this manager is an orthogonal service, it is depicted vertical and covers all three middleware layers.

Anmerkungen

Ein Verweis auf die Quelle fehlt.

Sichter
(Hindemith) Schumann